Laser Treatment System EM-270M

Laser Treatment System is designed for broaching profile channels (holes) in hard and superhard materials, such as natural and synthetic diamond, ruby, hard allows, aluminum ceramics, etc.
Using this technology profile channels (holes) which meet strict requirements to surface geometry and roughness are processed during one completely automated laser treatment operation, and there is no need to reset a part processed.
The primary application is to broach profile channels (holes) in diamond and diamond-like dice used to produce metalcords, cable wires, and other products made by drawing through the grooved die holes.
The technology covers practically the whole diameter range of industrial diamond dice from 0.1 to 5.0 mm. The accuracy of treatment is 2% of die diameter. The attainable accuracy of treatment in finishing mode is 3 mm. The system is also suitable for die repair (profile channel boring), products treatment around the inner and outer contours. Laser marking of die frame surfaces can be operated as well. Combined laser and TV channels enable receipt on SVGA “live” videopicture of the object for orientation of the workpiece and further inspection of treatment quality and processed hole diameter. A solid-state Nd:YAG laser with Q-switch is used in the system as a laser source. Service life of laser heat is at least 10000 hours. Service life of pump lamp is at least 400 hours.
Laser power supply and cooling unit contains the system for selection and stabilisation of cooling water temperature. This allows to maintain the average power of laser radiation at high stability level. Interlocks of minimal flow of the cooling water and of its max temperature allows to enhance reliability and service life of the laser.
The Laser Treatment System is controlled by IBM PC. Working program is made both with the use of own graphics editor and AUTOCAD editor. The computer allows to automatically select an optimum travel algorithm and the laser Q-switch control depending on the thickness of the processed material, its shape and contour of laser processing.
Specifications: Laser
 |
 |
| *Type |
Q-switched, Nd:YAG, Lamp pump |
 |
| *Operating mode |
TEM00, circular and linear polarisation |
 |
| *Wave Length |
1064 nm |
 |
| *Average Power |
15 Watt |
 |
| *Pulse Width |
~ 85 ns |
 |
| Q-Switch Frequency |
1-25 kHz |
 |
|
 |
Positioning System
 |
 |
| Field Size |
25 õ 25 mm |
 |
| Precision |
3 µm |
 |
| Speed of linear movement |
up to 5 mm/s |
 |
| Drive ** |
5-coordinate step drive |
 |
| *Power requirements |
380/230 V, 50 Hz, 6.5 kW |
 |
| *Overall dimensions |
1500 x 900 x1400 mm |
 |
| *Weight |
550 kg |
 |
| Note: - features marked * are reference data. |
|
 |
|
 |
**) Drive:
5-coordinate step drive with feedback on a position
controlled through Pentium IBM PC
Viewing Optics TV-channel enables receipt on SVGA monitor “live“ videopicture
of the object for orientation of the workpiece followed
by inspection of the processed hole diameter.
Control and Software System
The control system is based on PC and provides the
following:
- control to all drives in automatic processing mode
and orientation mode;
- storage and automatic selection of treatment
modes according to preset process parameters;
- editing of profile channel layout within its own
program;
- editing of marking layout using AUTOCAD;
- editing of scribing layout within its own program;
- inspection of average laser power with display of
pictogram on computer screen;
- control to R.F. driver;
- display on computer screen of TV-picture of surface
of the workpiece during its orientation;
- display on TV-screen of the on-line information
(absolute and relative coordinates of the stage, process
steps, prompting of operations sequence, treatment
time, error warning, etc.);
- execution of special debugging operations (search
for beam focus, its alignment with finder cross-hairs,
etc.);
- creation and storage of the library of programs
of operations including type of operation (via cutting,
scribing), layout pattern and list of process parameters;
- power-units diagnostics.
Operation Conditions
- Ambient temperature: 22°C±5°C
- Relative humidity: not more than 85%
- Power requirements: 3-phase 4-wire with neutral
380/220VAC, (50±2%) Hz, impulse noises protected.
Maximum voltage deviation from nominal: 10 %. For
power supply a separate electric power line must be
used. High-voltage and switching equipment like welding
devices , electrical ovens, metal-cutting machines,
etc. must not be connected to the distribution board
of this line.
- Compressed air to be supplied to the system under
pressure 0.5...0.6 Mpa (5...6 kgf/cm2).
Compressed air consumption is 1.5 m3/h.
Compressed air shall be supplied by means of a flexible
PVC pipe with outer diameter 10 mm and wall thickness
1.5 mm. The temperature of the air to be supplied
to the system shall not deviate from the room temperature
more than 5°C.
- The system must be connected to the vacuum with
residual pressure (3.4...4)*104 Pa, the connection
shall be supplied by means of a flexible PVC pipe
with inner diameter 6 mm.
- The system must be connected to exhaust ventilation
line with the pressure not less than 10 kPa (or to
a vacuum cleaner with power at least 1 kW).
The system should be connected to exhaust ventilation
by means of flexible corrugated tube with inside diameter
34 mm and outside diameter 43mm (supplied).
- Water under pressure 0.1...0.2 Mpa (1...2 kgf/cm2)
with flow rate not less than 10 l/min and temperature
not more than 18°C with free drain of waste water.
- The inner laser cooling system is filled with distilled
water (10 liters).
- Grounding.
- Floor space 10 m2.

|
 |